ACCA Manual S · Equipment Selection

What Is Manual S? A Complete Guide to HVAC Equipment Sizing

ACCA Manual S uses a home's Manual J heating and cooling loads, together with manufacturer performance data, to select residential HVAC equipment. It evaluates equipment capacity at the project's design conditions and applies the appropriate sizing requirements.

Three-step Manual S illustration showing Manual J loads, manufacturer performance data, and equipment selection.
Fig. 1 — Manual S uses Manual J loads and manufacturer performance data to select HVAC equipment.

The Manual S Standard Explained

Selecting Equipment Based on Actual Loads

Manual S is the ACCA (Air Conditioning Contractors of America) standard for residential HVAC equipment selection. After Manual J calculates a home's heating and cooling loads, Manual S provides the procedures for evaluating equipment against those loads and the applicable sizing requirements.

A unit's nominal tonnage or advertised BTU capacity does not tell the whole story. Manual S uses manufacturer performance data to evaluate heating capacity and both sensible cooling capacity (temperature control) and latent cooling capacity (moisture removal) at the project's design conditions.

Where required by the local permitting authority, Manual S documentation is submitted with the Manual J load calculation. Check local requirements for the applicable code edition and any additional HVAC design forms or reports.

Why Manual S Matters

Why Equipment Selection Requires More Than Matching BTUs

Sensible vs. Latent Capacity

Cooling equipment must address both temperature control (sensible load) and moisture removal (latent load). Manual S evaluates these capacities at the project's design conditions.

Manufacturer Performance Data

Manufacturer expanded performance data shows equipment capacity at specific temperatures and airflow settings. Nominal tonnage and standard rating conditions alone are insufficient for equipment selection.

Oversizing Consequences

Substantially oversized cooling equipment may run short cycles and provide inadequate moisture removal. The effects depend on the equipment's capacity control, operating conditions, and installation.

Undersizing Consequences

Equipment with insufficient capacity may struggle to maintain indoor design temperatures. Manual S applies sizing requirements appropriate to the equipment type and application.

Code Compliance

Where required by the local permitting authority, Manual S documents equipment selection alongside Manual J loads. Check local requirements for additional forms and reports.

System Integration

Manual J calculates the loads, Manual S selects equipment and establishes its design airflow, and Manual D uses that airflow to design the duct system. These steps must be coordinated.

The Manual S Selection Process

How Manual S Equipment Selection Works

01

Start with Manual J Results

Use the home's heating load and its total, sensible, and latent cooling loads as the basis for equipment selection. Carry forward the project's indoor and outdoor design conditions.

02

Obtain Manufacturer Performance Data

Obtain expanded performance data for the proposed equipment combination. Evaluate capacity at the project's design temperatures and selected airflow.

03

Evaluate Heating and Cooling Capacity

Compare heating capacity and total, sensible, and latent cooling capacities with the corresponding Manual J loads. For heat pumps, evaluate supplemental heating needs where applicable.

04

Verify Sizing Within Acceptable Limits

Apply the Manual S sizing requirements for the equipment type and application. Evaluate both adequate capacity and allowable oversizing, including any applicable exceptions.

05

Document the Selection

Record equipment model numbers, design conditions, selected airflow, performance data, and sizing comparisons. Provide the documentation required for the project and local permit review.

Four panels showing Manual S evaluation of heating capacity, cooling capacity, design airflow, and sizing requirements.
Fig. 2 — Manual S evaluates equipment capacities, design airflow, and applicable sizing requirements using manufacturer performance data.
Residential HVAC design sequence showing Manual J load calculations, Manual S equipment selection and design airflow, and Manual D duct design, with Manual S highlighted.
Fig. 3 — Manual J load calculations, Manual S equipment selection, and Manual D duct design work together in the residential HVAC design sequence.

Manual J → Manual S → Manual D

Manual S in the Residential HVAC Design Sequence

Manual S is the second step in the ACCA residential HVAC design sequence. Manual J establishes the home's heating and cooling loads. Manual S uses those loads and manufacturer performance data to select equipment and establish design airflow. Manual D then uses the airflow requirements, blower performance, and available static pressure to size and lay out the duct system. These steps must be coordinated.

Manual S Topics

Manual S Equipment Selection Topics

Manual S Equipment Selection: What It Is and Why It Matters

An overview of the ACCA Manual S standard, what it governs, and why a formal equipment selection procedure is required.

Read more

Manual S OEM Performance Data

How manufacturer expanded performance data is used in Manual S to evaluate equipment capacity at a project's design conditions.

Read more

How Manual S Determines the Right HVAC Equipment

The process Manual S uses to compare equipment performance data against Manual J loads and apply sizing requirements.

Read more

Manual S Heating and Cooling Equipment Sizing Explained

How Manual S evaluates heating capacity and both sensible and latent cooling capacity under the applicable sizing requirements.

Read more

Manual S Equipment Selection for New Construction Homes

How Manual S applies to new construction projects, where equipment is selected from plans before the building is complete.

Read more

Manual S Equipment Selection for Existing Homes and HVAC Replacement

How Manual S applies to replacement projects and why using the previous unit's size without a load calculation can perpetuate sizing problems.

Read more

Manual S Equipment Selection for Heat Pumps

How Manual S evaluates heat pump heating and cooling capacity at design conditions and addresses supplemental heating requirements.

Read more

Manual S Equipment Selection for Air Conditioners and Furnaces

How Manual S evaluates split systems pairing an air conditioner with a gas furnace or air handler.

Read more

Manual S Equipment Sizing Mistakes: Common Errors to Avoid

Common errors in equipment sizing, including using nominal ratings instead of performance data and skipping latent capacity evaluation.

Read more

Why Oversized HVAC Systems Are a Problem

How substantially oversized cooling equipment can affect system performance and why Manual S applies sizing limits.

Read more

How Manual S Prevents Undersized and Oversized Equipment

How Manual S sizing requirements address both insufficient capacity and excessive oversizing for different equipment types.

Read more